All guides

Methodology

How Verith picks a range: our evidence ladder

Labs disagree about what's normal more often than most people realize. Here's the order of evidence Verith uses to choose every range, and the rules that keep longevity targets honest.

7 min read Updated Verith Team
A three-rung ladder: independent source, median of labs, single lab

Every range in Verith comes from the highest rung of an evidence ladder: an independent source such as a clinical guideline first, then the median of several major labs, and a single lab only as a last resort. We also never let a “longevity” target grade a result better than the standard clinical range would.

Why this matters

You’d expect “normal” to be a settled number. It isn’t. We compared the reference ranges that major North American labs publish for 18 markers. For 59 of 71 ranges, the labs’ limits differed by more than 20% of the range’s width. The same result can be flagged at one lab and pass at another.

Most apps quietly pick one lab’s numbers, or invent an “optimal” band in the middle of the normal range. We wanted a rule we could explain, apply the same way every time, and show you on every marker.

In short

Verith grades every marker on one written rule, applies it the same way whichever lab your result came from, and shows its working.

  • One range per marker, not one per lab. A result is graded against the same range whether it came from Quest, Labcorp, LifeLabs or a membership, so changing labs never changes your grade on its own.
  • Every grade names its source. Each graded marker says where its range came from: a guideline, a public source or a lab consensus. Consensus ranges show how many labs they’re based on, and say so when those labs disagree widely.
  • Longevity targets that can’t flatter you. A target exists only where a source states one, and it can never grade a result better than the clinical range would.
  • Open to correction. If you know of newer evidence, send it to [email protected]. If it holds up, the range is updated in the app for everyone.

The ladder

We use the first rung that has a source that fits.

RungSourceExample
1. IndependentA clinical guideline, a public government source, or an openly licensed studyVitamin D from the US National Institutes of Health
2. Lab consensusThe median of two or more major clinical labs, taken separately for the low and high limitsMost routine chemistry markers
3. Single labOne lab’s published range, flagged as suchSpecialty tests few labs run

Three markers show each rung in practice:

Two rules keep the ladder honest.

The source has to fit the people using Verith: within 20%, or it doesn’t set the grade. A study from a single country only counts if its numbers agree with North American labs, or with an independent study from somewhere else, within 20%. A careful study that fails this test can still appear as a note. Fasting insulin is an example: a large Brazilian study of healthy adults shows up as a note, while the grade follows North American labs. A range measured on one specific machine only counts if the labs our users go to run that machine.

A reprint counts once. If one lab simply sends a test to another lab and prints its range, that’s one lab’s opinion, not two.

Two kinds of “normal”

Not every range means the same thing, so we keep track of which kind we’re using.

When a source names its own categories, we keep them. A guideline’s “optimal” becomes our top grade, its “borderline” becomes Fair, and so on. We don’t stretch or merge them to make a tidier picture.

Longevity targets: stricter, never looser

Longevity mode shows targets for the lowest risk the evidence supports, not just “within normal”. Three rules govern them, and our guide on why we don’t invent “optimal” goes into each:

  1. A target only exists where a source states one. If no study or guideline names an optimum, we don’t make one up from the middle of the normal range. The marker keeps its standard grade, and the app says why.
  2. A longevity target can never grade you better than the clinical range would. It can show you room to improve, or flag something sooner. It can’t call a result “optimal” when the standard range calls it borderline.
  3. Popular targets get checked, not copied. When a widely shared target isn’t supported by outcome studies, we say so instead of adopting it.

Where good sources disagree, we pick a default by strength of evidence, how well it fits our users, whether it’s reachable, and the cost of being wrong. The alternatives stay available, labeled as alternatives.

What we don’t know

Some markers don’t have a range anyone can defend. For example, some hormones can’t be read without knowing the menstrual cycle phase, and a few ratios have no published cut-offs at all. Those markers are tracked but not graded, with a note explaining why.

And evidence changes. Every range has a decision record with a review date and a list of what would make us reopen it, such as a new guideline or a second outcome study.

Keeping it current, together

A range is only as current as the research behind it, and new guidelines and studies appear every month. Many people who track their bloodwork follow that research closely, and they often spot a change before it reaches a lab report.

So we treat every range as open to correction. If you see a newer guideline, a better study or a source we’ve misread, email it to [email protected] with a link. We check it against the same ladder and rules above. If it holds up, we update the range in the app and record what changed and why, so everyone’s results are graded against the latest science.

What this means for you

When Verith grades a result, it tells you where the range came from. If your lab’s printed range differs from ours, that’s usually the reason: labs genuinely disagree, and we’re showing you a consensus or a guideline instead of one lab’s number. If a difference matters for a decision, it’s a good question to bring to your clinician.

Not medical advice. Talk to your healthcare provider about your results.

Sources

  1. Clinical and Laboratory Standards Institute (2010, reaffirmed 2020) — EP28-A3c: Defining, establishing, and verifying reference intervals in the clinical laboratory
  2. Open-access review of how reference intervals are established (PubMed Central)

Get new guides and launch news