The same result can be in range at one lab and flagged at another. In October 2026 we compared the reference ranges that five major North American labs publish. Of the 71 ranges with both limits from at least two labs, 59 differed by more than 20% of the range’s width. For 44, the gap was more than 30%. That applies to the 18 markers and five labs we compared; routine chemistry markers weren’t included.
In short
Verith grades each marker against one range, whichever lab ran your test, and names the source behind it. If your result lands where labs set the limits differently, Verith adds a note showing the spread. Each result keeps its lab, date, units and method, so a change of lab doesn’t break your trend.
Why this matters
A flag on a lab report feels like a verdict. But the line it’s drawn against was set by that lab, from its own data and its own choices. Move the same blood to another lab and the flag can appear or disappear.
That matters most when you switch labs, or compare a result with a friend’s. It’s also why a single flag is a reason to look closer, not a conclusion.
How much labs disagree
Our analysis covered 18 markers where Verith compared several labs’ ranges: mostly hormones, plus apoA1, total PSA, zinc, fibrinogen and fasting insulin. Where labs split a range by sex or age, we compared each band separately. That gave 71 ranges with both a low and a high limit from at least two labs. The labs were Dynacare, Labcorp, LifeLabs, Mayo Clinic Laboratories and Quest Diagnostics.
For each range we asked how far apart the labs’ low limits were, and how far apart their high limits were. We counted a range as a disagreement when either gap was more than a fifth of the range’s typical width. By that measure, 59 of 71 disagreed. Routine chemistry markers weren’t part of this comparison, so these figures don’t speak for them.
How we counted a disagreement
- Markers (18): apoA1, C-peptide, morning cortisol, afternoon cortisol, DHEA-S, DHT, estradiol, fasting insulin, fibrinogen, FSH, IGF-1, LH, progesterone, total PSA, reverse T3, SHBG, total testosterone and zinc.
- Labs (5): Dynacare, Labcorp, LifeLabs, Mayo Clinic Laboratories and Quest Diagnostics, with ranges read from each lab’s published test pages in October 2026 and compared on 17 October 2026.
- A range is one marker for one sex and age band. It counts if at least two labs publish both a low and a high limit for it: 71 did.
- Converting: every limit is put into the same unit first.
- The typical width is the distance between the median low limit and the median high limit across the labs.
- The gap for a limit is the highest lab’s value minus the lowest lab’s value.
- A disagreement is a range where the gap at either limit is more than 20% of the typical width: 59 of 71. At 30%, it’s 44.
Here are four examples, checked on each lab’s own test page in November 2026.
| Marker | One lab | Another lab | The same result |
|---|---|---|---|
| Zinc, adults | Mayo: 60–106 mcg/dL (9.2–16.2 µmol/L) | Quest: 60–130 mcg/dL (9.2–19.9 µmol/L) | 120 mcg/dL (18.4 µmol/L): high at Mayo, in range at Quest |
| SHBG, men | Quest, ages 18–55: 10–50 nmol/L | Mayo, 18 and over: 13.3–89.5 nmol/L | 60 nmol/L: high at Quest, in range at Mayo |
| Fasting insulin | Quest: 18.4 µIU/mL or below (128 pmol/L or below) | Labcorp: 2.6–24.9 µIU/mL (18–173 pmol/L) | 21 µIU/mL (146 pmol/L): high at Quest, in range at Labcorp |
| Fibrinogen | Quest, antigen test: 180–350 mg/dL (1.8–3.5 g/L) | Labcorp, activity test: 209–464 mg/dL (2.1–4.6 g/L) | 400 mg/dL (4.0 g/L): high at Quest, in range at Labcorp |
Labcorp’s range for ages 11 months and up, 44–115 mcg/dL (6.7–17.6 µmol/L), would flag that 120 too. Its SHBG range for men aged 20 to 49 is 16.5–55.9 nmol/L, so 60 is high there as well.
Why labs differ
Method. Different instruments and chemistry give different numbers from the same blood. The fibrinogen pair above isn’t even the same test. Quest measures the amount of fibrinogen protein; Labcorp measures how well it forms a clot.
The reference population. A reference interval is usually the middle 95% of results from a group of healthy people. Who counts as healthy, and how many were tested, varies from lab to lab. A 2024 review notes that method bias and population differences can stop ranges from transferring between labs.
Age and sex bands. Labs cut the bands in different places. For SHBG in men, Quest uses 18 to 55, Labcorp 20 to 49 and Mayo 18 and over. A 52-year-old is compared with a different group at each.
Rounding and units. Limits get rounded, and converting between units such as mcg/dL and µmol/L shifts them a little more. That’s a small effect, but it adds up at the edges.
Sometimes we can’t tell which reason matters most. All three labs measure zinc by ICP-MS, a type of mass spectrometry. Yet their high limits still run from 106 to 130 mcg/dL.
Two kinds of “normal”
Not every line on a report means the same thing.
- A reference interval describes healthy people: the middle 95%. By design, about 1 in 20 healthy people falls outside it. A result outside it is unusual, not necessarily a problem.
- A risk threshold marks where a guideline says risk or disease begins. It comes from outcome studies, not from describing a healthy group.
HbA1c is a clear risk-threshold example. The American Diabetes Association’s 2026 Standards of Care define 5.7–6.4% (39–47 mmol/mol) as prediabetes and 6.5% (48 mmol/mol) or higher as diabetes. LDL cholesterol is another. The 2001 ATP III guideline calls below 100 mg/dL (2.6 mmol/L) optimal and 190 mg/dL (4.9 mmol/L) or higher very high.
A risk threshold doesn’t change with the lab, as long as the test is standardized. For HbA1c, the ADA asks for a certified method standardized to the assay used in its outcome trials.
Sometimes a report blends the two kinds. Quest’s insulin page, for example, presents its 18.4 µIU/mL limit as a cardiovascular risk category based on its own reference interval studies. Lipid reports often do it too: an LDL cholesterol limit of 100 mg/dL (2.6 mmol/L) printed in the reference-range column is ATP III’s “optimal” cut-off, not the middle 95% of healthy people. Many healthy adults sit above it.
How Verith treats each kind
The two kinds need different handling, so Verith keeps them apart. The full rules are in How Verith picks a range; stricter longevity targets follow the separate rules in We don’t invent “optimal”.
For reference intervals, Verith uses one range per marker: an independent source where one fits, otherwise the median of several major labs. That gives the same grade whichever lab ran your test. For risk thresholds, Verith keeps the guideline’s own categories. For HbA1c, below 5.7% is Strong, 5.7–6.4% is Flagged, and 6.5% or higher is Priority.
What we don’t know
Labs rarely publish how they set each range: how many people, how they were screened, and which statistics were used. So for many disagreements we can describe the gap but not fully explain it. Our comparison is also a snapshot: labs update ranges, and the figures above reflect their pages as of the dates given.
What this means for you
Compare results from the same lab over time when you can. The differences between labs can be as large as the change you’re trying to see. A move from Labcorp to Quest can make a result look better or worse when nothing in your body changed.
If you do switch labs, note when it happened and read your trend with that in mind. If a result is flagged at one lab but not another, that’s a good question to bring to your clinician. Our guide on switching testing providers covers keeping your history together.
Not medical advice. Talk to your healthcare provider about your results.